Main technical characteristics
1. Adopt the principle of potential titration method, configure the desktop computer, use the Windows operating platform and Chinese software interface, mouse, keyboard operation, man-machine dialogue.
2, the use of micro-computer automatic measurement, automatic printing, the test process to achieve microcomputer automation, intuitive and simple operation.
3, the selection of imported titration unit, stable and reliable performance, high measurement accuracy, very low transmission noise, good stability.
4. Multi-parameter setting and correction make the analysis of different kinds of samples simple, fast, shorter analysis time and the results more accurate.
5. Automatic judgment of end point and automatic filtration of false end point; without indicator, it is suitable for acid value analysis of various light and dark oil in petrochemical products, titration results and data storage, and can provide complete titration data for analysis and research.
6. Double-high resistance input, three-electrode system, the electrode potential is more stable and reliable; titration results and data storage.
7. If there are few test samples, only (0.1~5) g for each time, the test time is fast, and the test time of each test sample is about 5 minutes.
8. Display the test process curve and test results in real time. Can realize the test curve of printing, test results and test data (printer is the purchase).
9, automatic rehydration, automatic fixed value of adding fluid.
Main technical parameters and indicators
1. Measuring range: (0.1~300) mgKOH / g;
4. Potential measurement range: (0~ ± 2000) mv;
5. Basic error of electronic unit: 0.1%F ± 0.5 mv;
6. Input impedance: Ri 11012 Ω;
7, titer tube volume: 10ml;
8. Minimum volume of tipper: 0.001ml (minimum feed liquid);
9. Titration tube accuracy: ± 0.1% FS;
10. Titration tube drop time: (60 ± 10) seconds (FS);
11, Acid value determination range: 0.05 mgKOH / g
12, the ambient temperature: 10℃ ~40℃;
13. Relative humidity: not more than 85%;
14. Working power supply: AC (220 ± 10) V, (50 ± 0.5) Hz, 300W (total power);
15, instrument weight: 12 Kg (tester host, excluding computer, printer, etc.);
Product Details
-
ZDHW-600B Microcomputer Total Self Momentum Thermometer
-
ZDHW-600C Microcomputer Fully Automatic Calorimeter
-
YHCS-2000 High Frequency Infrared Carbon and Sulfur Analyzer
-
KZCH-7A Microcomputer Automatic Hydrogen Analyzer
-
YHZD-1000B Hydrolysis Combustion Nitrogen Analyzer
-
KZDL-700B microcomputer automatic sulfur analyzer